Change in Class Location (16.2)
Criticality: High
Progress: Not Addressed
Score: 40
DOT Relevance: §192.609 – §192.611
Description of Key Area
The subject of change in class location falls under the Subpart L (Operations) of 49 CFR 192. Class location refers to the distance a structure must be located from the pipeline. A “class location unit” is defined in 49 CFR 192 as “an on-shore area that extends 220 yards on either side of the centerline of any continuous 1-mile length of pipeline.”
Discussion of Criticality
The parameters for class location are based on natural gas considerations. The underlying definition of class location should be reviewed for hydrogen.
Discussion of Progress
ASME B31.12 plans on following the ASME B31.8 code with input from the modified section 3.2 of ASME B31.8S.
Recommendations
Standards should be established for change in class location of hydrogen pipelines and incorporated by reference into the federal code including what the maximum allowable operating pressure of the hydrogen pipe should be and at what population density is a change in class location warranted. The class location unit needs to be revisited to confirm whether it is appropriate for hydrogen. The change in class location criteria in 49 CFR 192 also should be revisited.

